SEYMOUR
‹
›
Technical Specifications
Enclosure Protection
Explosion proof Ex d IIC T6 Gb, O-ring
Ingress Protection
IP67 (Option IP68)
Coating
No painting on stainless steel housing
Area / Gas Group Class
Zone 1,2 / IIC
Switches(Sensors)
2-SPDT mechnical switch(Form C)
Cable Entries
2- M20 (Option : 2- G3/4, M25, NPT3/4)
Terminal
8 or 12 nos of terminal strips (6 for switches, 2 for solenoid valve power)
Position Monitoring Indication
Dome type 0°~90°
Switch Rating
16A 1/2HP 125/250V AC, 0.6A 125V DC, 0.3A 250V DC
Mounting Bracket
Stainless Steel acc.to VDI/VCE3845, NAMUR, SS1, SS2, as Standard
Certification
KC, IECEX, GOST-RTN, ATEX
SIMMEL can provide you with customized actuator solutions.